適用范圍
1、防爆場所:1區、2區的IA~IIC類爆炸性(xing)氣體環境;
2、溫(wen)度組別:T1~T6;
3、環境要(yao)求:戶(hu)外、戶(hu)內、IP54、IP65、IP66 *
主要技術參數
防爆標志:ExdelB(C)T4/T5/T6 Gb;
額定電(dian)壓:24/36/110/220/230/240/380/415/500/690V;
支路(lu)電(dian)流:≤630A:
主回路(lu)電流:IP54、IP65、IP66,(訂購時(shi)需提1):T6≤32A、T5≤63A、T4≤400A;
產品特點(dian):外殼采(cai)用優(you)質鋼板(ban)焊(han)接成型,表面(mian)高壓靜(jing)電(dian)噴(pen)塑,或不銹(xiu)鋼板(ban)焊(han)接成型。內裝各種(zhong)防爆電(dian)器(qi),可按照用戶提(ti)供的電(dian)氣原理圖(tu)及主要技(ji)術(shu)參數制(zhi)定配電(dian)柜的外形尺寸并選用相應的防電(dian)器(qi),可根據要求制(zhi)作(zuo)(zuo)成面(mian)板(ban)上直接操(cao)作(zuo)(zuo)或開門操(cao)作(zuo)(zuo)等形式(shi)。常見方案(an)舉例:
a、多(duo)路動(dong)力(照明) 配(pei)電(dian)(dian)(dian)型通過將多(duo)個防爆斷路器或動(dong)力(照明)配(pei)電(dian)(dian)(dian)箱(xiang)及(ji)數個防爆接線箱(xiang)組合(he),可在(zai)電(dian)(dian)(dian)壓380V,電(dian)(dian)(dian)流630A的三相交(jiao)流50Hz的配(pei)電(dian)(dian)(dian)系統中實現動(dong)力、照明配(pei)電(dian)(dian)(dian)設備的電(dian)(dian)(dian)能轉換分配(pei)及(ji)控制。
b、多路(lu)電磁走動配(pei)申型
通過將多(duo)個防(fang)爆(bao)電(dian)磁(ci)起動器或電(dian)磁(ci)起動箱(xiang)和防(fang)爆(bao)斷路(lu)(lu)器、操作柱(zhu)和防(fang)爆(bao)接(jie)線箱(xiang)等(deng)組合,可(ke)在電(dian)壓 380V的三相交流(liu)(liu)50Hz的配電(dian)系(xi)統中(zhong)實(shi)現動力配送及電(dian)動機的集中(zhong)控(kong)制,支路(lu)(lu)最大(da)可(ke)達到225A,可(ke)根(gen)(gen)據(ju)用戶要(yao)求實(shi)現遠(yuan)距離控(kong)制,并可(ke)根(gen)(gen)據(ju)要(yao)求加裝(zhuang)(zhuang)信號(hao)燈、電(dian)壓表、電(dian)流(liu)(liu)表等(deng)監控(kong)裝(zhuang)(zhuang)置,多(duo)路(lu)(lu)降壓起動配電(dian)型.
C 、將(jiang)防爆降(jiang)(jiang)壓(ya)起(qi)動(dong)箱置于(yu)防護柜中,實現對交(jiao)流(liu)50Hz、電壓(ya)為380V,電路中容量為95KW及以下的(de)三(san)相鼠籠(long)型電動(dong)機的(de)不頻繁降(jiang)(jiang)壓(ya)起(qi)動(dong),具有短(duan)路、缺相、過(guo)流(liu)堵(du)轉等(deng)保護功能,可(ke)用手動(dong)、自動(dong)和遠控等(deng)多種方式來控制(zhi)。